Sale!

Original price was: ₹5,000.00.Current price is: ₹3,700.00.

- +
Guaranteed Safe Checkout

Online PH Meter Nashik

10 Days Returnable;
Heavy Duty Industrial Use
1 Year Warranty and nominal Life 6-7 years in a Normal Atmosphere.
Sensors No Warranty.”

Contact Us:- 8178668698; 9310530941; An ISO 9001-2015 Certified Company.

 

Online PH Meter Nashik – Digital pH Meter for Industrial Water Monitoring

UMA Industries supplies reliable Online PH Meter Nashik
solutions for continuous measurement of acidity and alkalinity in water,
wastewater, chemical solutions and industrial process liquids. Our
panel-mounted instruments are suitable for ETP plants, STP plants, RO plants,
DM plants, electroplating units, automotive industries, pharmaceutical
utilities, food-processing plants, cooling towers, boiler-water systems and
industrial process applications.

Online PH Meter Nashik
Digital online pH meter for continuous monitoring of industrial water,
wastewater and chemical process liquids in Nashik.

Industrial Online PH Meter Nashik

An Online PH Meter Nashik continuously receives the signal
generated by a compatible pH electrode and converts it into a clear digital
pH reading. Continuous measurement helps operators identify changes in the
process immediately instead of depending only on periodic laboratory sampling.

The pH scale generally ranges from 0 to 14. A value below 7 indicates an
acidic liquid, 7 represents a neutral condition and a value above 7 indicates
an alkaline liquid. Monitoring the correct pH supports wastewater
neutralisation, chemical dosing, treatment efficiency, corrosion control,
production quality and stable process operation.

Depending on the selected instrument, relay output, alarm indication,
analogue output or RS485 Modbus RTU communication can be provided. These
output options allow the meter to work with dosing systems, PLCs, HMIs,
SCADA systems, data loggers, recorders and industrial automation panels.

Main Features of Online PH Meter Nashik

  • Continuous online measurement of water and process-liquid pH
  • Common measuring range from 0 to 14 pH
  • Clear digital display for convenient process observation
  • Panel-mounted design for industrial control panels
  • Compatible pH electrode input with BNC connector
  • Two-point calibration using standard pH buffer solutions
  • High and low alarm options, depending on the selected model
  • Relay-output model for dosing pump, valve, alarm or interlock
  • Optional 4–20 mA retransmission output
  • Optional 0–10 VDC output through a suitable model
  • Optional RS485 Modbus RTU communication
  • Compatible with PLC, HMI, SCADA and data-logging systems
  • Suitable for tank, pipeline, flow-cell and sampling-pot installations
  • Suitable for continuous industrial operation

Technical Specifications

The following are typical specifications for an
Online PH Meter Nashik. Final specifications depend on the
selected model, pH electrode, output requirement, process temperature and
installation arrangement.

Technical ParameterTypical Specification
Measured parameterpH
Common measurement range0.00 to 14.00 pH
Display resolutionModel dependent; fine digital pH indication available
DisplayBright digital LED or LCD display, depending on model
Measurement methodContinuous online measurement using a compatible pH electrode
Sensor connectionBNC connector or model-specific electrode connection
Standard calibrationTwo-point calibration using pH 7.00 and pH 4.00 buffers
Alkaline-range calibrationpH 7.00 and pH 9.20 or 10.00 where supported
Temperature compensationManual or automatic, depending on model and electrode
Alarm or relay outputAvailable through selected meter and controller models
Analogue output4–20 mA or 0–10 VDC through selected models
Digital communicationRS485 Modbus RTU through a communication-enabled model
MountingPanel-mounted online instrument
Electrode installationTank, pipeline, flow cell, immersion holder or sampling chamber
Power supplyIndustrial AC or DC supply according to model
Typical applicationsETP, STP, RO, DM, plating, chemical and utility-water systems

Working Principle of an Online pH Meter

A pH electrode contains a sensitive glass membrane and a reference system.
When the electrode comes into contact with the process liquid, it produces a
small electrical potential related to hydrogen-ion activity. The online meter
processes this electrode signal, applies the calibration values and displays
the corresponding pH reading.

The electrode may be installed in a process tank, neutralisation vessel,
pipeline, effluent channel, flow cell or sampling chamber. The electronic
display is generally mounted inside a control panel where plant personnel can
continuously observe the live value.

A meter equipped with relay output can operate an alarm, valve or dosing
arrangement when the measured value crosses a programmed limit. A Modbus or
analogue-output model can transmit the pH value to a central automation or
monitoring system.

Difference Between Online pH Meter and pH Controller

An online pH meter mainly measures and displays the current pH value. A pH
controller performs the measurement and also provides control outputs for
operating acid pumps, alkali pumps, solenoid valves, alarms or process
interlocks.

Select a standard online meter when continuous indication is required. Select
a pH controller with suitable set points and relay outputs when automatic
correction of acidic or alkaline conditions is required.

Calibration of Online PH Meter Nashik

Regular calibration is essential for dependable operation of an
Online PH Meter Nashik. Electrode ageing, chemical exposure,
contamination, sludge, oil and scale can gradually affect sensor response.
Cleaning and calibration compensate for these changes.

Items Required for Calibration

  • Fresh pH 7.00 buffer solution
  • Fresh pH 4.00 buffer solution
  • pH 9.20 or pH 10.00 buffer for alkaline-range applications
  • Clean distilled or demineralised water
  • Separate clean beakers for every buffer
  • Soft tissue for gently removing excess liquid
  • Calibration and maintenance record sheet

Step-by-Step Calibration Procedure

  1. Switch on the meter and allow the instrument to stabilise.
  2. Remove the electrode carefully from the tank, pipeline or sampling chamber.
  3. Inspect the sensing bulb, cable and connector for deposits or physical damage.
  4. Clean the electrode using a method suitable for the process contamination.
  5. Rinse the electrode with distilled or demineralised water.
  6. Gently shake off excess water without rubbing the sensitive glass bulb.
  7. Place the electrode in fresh pH 7.00 buffer solution.
  8. Wait until the displayed value becomes stable.
  9. Adjust or confirm the neutral calibration according to the meter controls.
  10. Remove the electrode and rinse it again with clean water.
  11. Place the sensor in pH 4.00 buffer for acidic-range measurement.
  12. Use pH 9.20 or pH 10.00 buffer for a suitable alkaline-range application.
  13. Wait for the reading to stabilise and perform the second calibration point.
  14. Rinse the electrode and verify it again in pH 7.00 buffer.
  15. Reinstall the electrode and check the live process reading.
  16. Record the calibration date, buffer values and final readings.

Recommended Calibration Frequency

Calibration frequency depends on the liquid, operating conditions and required
accuracy. Clean-water systems may be checked weekly, fortnightly or monthly.
Wastewater, plating solutions, oily liquids, sludge and aggressive chemicals
may require more frequent cleaning and calibration.

Replace the electrode when it responds very slowly, fluctuates continuously
or cannot be calibrated properly after cleaning and inspection.

Uses of Online PH Meter Nashik

An Online PH Meter Nashik is used wherever continuous
liquid monitoring is required for water treatment, environmental management,
production quality, chemical dosing or process stability.

  • Effluent Treatment Plants:
    Monitoring collection tanks, neutralisation systems, treatment stages and
    final discharge water.
  • Sewage Treatment Plants:
    Monitoring inlet water, biological-treatment stages and treated outlet water.
  • RO and DM Plants:
    Checking feed water, treated water, reject water and chemical-dosing systems.
  • Automotive Industries:
    Monitoring pretreatment lines, paint-shop water, washing systems and plant ETPs.
  • Electroplating Plants:
    Monitoring process baths, rinse water, pretreatment systems and effluent.
  • Chemical Industries:
    Monitoring reaction liquids, mixing tanks, dosing skids and neutralisation vessels.
  • Pharmaceutical Utilities:
    Monitoring utility-water treatment and suitable process applications.
  • Food, Dairy and Beverage Plants:
    Monitoring process water, cleaning systems and wastewater.
  • Textile Industries:
    Monitoring bleaching, dyeing, washing, finishing and effluent-treatment stages.
  • Cooling Towers:
    Monitoring circulating water and chemical-treatment programmes.
  • Boiler-Water Systems:
    Supporting chemical treatment and corrosion-control programmes.
  • Paper and Pulp Plants:
    Monitoring process water and industrial wastewater.

Benefits of Online PH Meter Nashik

  • Continuous real-time pH indication
  • Reduced dependence on repeated manual sample testing
  • Faster identification of acidic or alkaline process changes
  • Improved wastewater-treatment consistency
  • Better supervision of chemical dosing
  • Reduced risk of excessive chemical addition
  • Improved product and process repeatability
  • High and low pH alarm options
  • Optional automatic dosing control
  • Optional PLC, HMI, SCADA and data-logging integration
  • Improved calibration and maintenance records

Selecting a Suitable pH Electrode

The pH electrode is the main sensing component of the measurement system.
Sensor selection should consider the liquid, temperature, pressure, suspended
solids, contamination, chemical compatibility, installation method and
required cable length.

  • General-purpose glass electrode for relatively clean water
  • Industrial immersion electrode for tanks and sumps
  • Flow-through electrode for pipelines and sampling chambers
  • Double-junction electrode for contaminated process liquids
  • Flat-surface electrode for viscous materials
  • High-temperature electrode for heated process liquids
  • Long-cable electrode for deep tanks and remote installations
  • Chemical-resistant electrode for aggressive industrial liquids

Installation Guidelines

Correct installation of the Online PH Meter Nashik and its
electrode helps reduce unstable readings, measurement errors and premature
electrode failure.

  1. Install the display instrument inside a clean and dry control panel.
  2. Protect the instrument from direct water spray and corrosive fumes.
  3. Install the electrode where the process liquid is properly mixed.
  4. Avoid positioning the sensor directly beside a chemical injection point.
  5. Keep the electrode bulb immersed during normal measurement.
  6. Avoid locations where air bubbles collect around the sensing bulb.
  7. Keep the electrode cable away from motors, VFDs and power cables.
  8. Provide correct panel earthing to reduce electrical interference.
  9. Use a suitable flow cell where direct tank installation is impractical.
  10. Provide sufficient access for sensor cleaning and calibration.

Maintenance and Safety Precautions

  • Never allow the pH electrode glass bulb to remain dry.
  • Store the electrode in a suitable electrode-storage solution.
  • Do not permanently store the electrode in distilled or DM water.
  • Do not clean the glass bulb using abrasive tools.
  • Use fresh and uncontaminated calibration buffers.
  • Never return used buffer to its original container.
  • Clean oil, sludge, scale and chemical deposits regularly.
  • Inspect the electrode cable and connector for moisture or damage.
  • Keep chemical leakage away from the electrical control panel.
  • Use suitable PPE while handling acids, alkalis and industrial chemicals.

Online PH Meter Nashik Supply Areas

UMA Industries supplies Online PH Meter Nashik products to
ETP contractors, OEM panel builders, automation companies, water-treatment
businesses, laboratories and industrial plants throughout Nashik and nearby
Maharashtra industrial regions.

Major Industrial Areas Around Nashik

  • Satpur MIDC
  • Ambad MIDC
  • Sinnar MIDC
  • Malegaon MIDC, Sinnar
  • Gonde Industrial Area
  • Igatpuri Industrial Area
  • Dindori Industrial Area
  • Ozar Industrial Area
  • Nashik Road Industrial Area
  • Pathardi and Vilholi industrial areas
  • Shinde and Palse industrial belt
  • Ghoti Industrial Area

Surrounding Industrial Cities

  • Sinnar:
    Automotive components, electrical equipment, engineering and fabrication units.
  • Igatpuri:
    Automotive, engineering, manufacturing and process industries.
  • Malegaon:
    Textile, fabrication, engineering and water-treatment applications.
  • Dhule:
    Engineering, textile, agricultural-equipment and process industries.
  • Jalgaon:
    Food processing, engineering, agricultural and fabrication units.
  • Ahmednagar:
    Automotive, machinery, engineering and metal-processing plants.
  • Chhatrapati Sambhajinagar:
    Automotive, pharmaceutical, electrical and process industries.
  • Pune and Chakan:
    Automotive, engineering, chemical and component-manufacturing industries.
  • Mumbai, Thane and Navi Mumbai:
    Chemical, pharmaceutical, food, engineering and water-treatment industries.

Other Products in the pH Meter Category

Buyers selecting an Online PH Meter Nashik can compare the
following UMA Industries products for continuous monitoring, automatic
control, RS485 communication and laboratory measurement.

External Technical Reference

For additional information about hydrogen-ion activity, acidic conditions,
alkaline conditions and the pH scale, visit the

United States Environmental Protection Agency technical reference on pH
.

Frequently Asked Questions

What is an online pH meter?

An online pH meter is an industrial instrument used for continuous
measurement of water, wastewater, chemical solutions and process liquids
through a connected pH electrode.

What is the common pH measurement range?

Industrial online pH meters commonly provide a measuring range from
approximately 0 to 14 pH. Final specifications depend on the selected model.

Where can the pH electrode be installed?

It can be installed in a tank, pipeline, flow cell, sampling chamber,
neutralisation vessel, effluent channel or water-treatment system.

Which buffer solutions are used for calibration?

pH 7.00 and pH 4.00 buffers are commonly used for two-point calibration.
A pH 9.20 or pH 10.00 buffer may be used for suitable alkaline applications.

How frequently should the meter be calibrated?

Calibration may be required weekly, fortnightly or monthly depending on the
liquid and required accuracy. Harsh or contaminated applications may require
more frequent calibration.

Can the meter control a dosing pump?

Selected relay-output or controller models can operate acid or alkali dosing
equipment through correctly designed electrical wiring and protection.

Is 4–20 mA output available?

Yes. A suitable pH meter model can provide 4–20 mA output for PLC, SCADA,
recorder or remote-display applications.

Is RS485 Modbus communication available?

Yes. Modbus 485 pH meter and RS485 pH controller models are available for
compatible industrial automation systems.

Why does the displayed pH reading fluctuate?

Common causes include a dirty or dry electrode, damaged cable, air bubbles,
poor earthing, electrical interference, contaminated buffers, inadequate
mixing or an ageing sensor.

Can one pH electrode be used for every chemical?

No. Electrode selection depends on chemical compatibility, temperature,
pressure, suspended solids, contamination and the mounting arrangement.

Can a pH electrode be stored dry?

A standard glass pH electrode should not remain dry for long periods. Store
it in the recommended electrode-storage solution.

Where can I buy Online PH Meter Nashik?

UMA Industries supplies Online PH Meter Nashik products
to Nashik, Satpur, Ambad, Sinnar, Gonde, Igatpuri, Dindori, Ozar, Malegaon,
Dhule, Jalgaon, Ahmednagar and nearby industrial areas.

What details are required for selecting the correct meter?

Provide the process-liquid name, expected pH range, temperature, pressure,
tank or pipeline arrangement, electrode cable length, output requirement,
communication requirement and installation location.

Order Online PH Meter Nashik

To select the correct Online PH Meter Nashik, share the
process-liquid details, expected measuring range, temperature, electrode
installation, required cable length and output requirements. UMA Industries
can recommend a suitable digital meter, industrial pH electrode, relay-output
instrument or RS485 Modbus model for your application.


Contact UMA Industries for online pH meters, digital pH controllers,
industrial pH electrodes, 4–20 mA instruments and RS485 Modbus meters
in Nashik.


Need help choosing? Call/WhatsApp us for industrial pH/ORP solutions.


Weight500 g
Dimensions12 × 11 × 11 cm

Reviews

There are no reviews yet.

Be the first to review “Online PH Meter Nashik”
🟢 WhatsApp Price 📞 Call Now
Scroll to Top