Digital Signal Operated Timer Manufacturer in Faridabad

Sale!

Original price was: ₹5,000.00.Current price is: ₹2,800.00.

- +
Guaranteed Safe Checkout

UMA Industries manufactures and supplies the Digital Signal Operated Timer for trigger-pulse based timing in industrial panels and control systems. It is manufactured at UMA Industries’ unit in Village Sunped, Ballabgarh, Faridabad, Haryana, India, and supported across India.

  • Works with a trigger pulse and starts timing after the input signal is received.
  • Preset time can be set through the front-panel keys as per the required process sequence.
  • Range, timing unit and display use are model-dependent and finalized during quotation.
  • Published website prices are company-confirmed; size, power supply and optional controls may be finalized in quotation.
  • Ready-stock compact products, controllers, spares and accessories may be dispatched by air courier within 3 working days, subject to availability, payment confirmation, destination serviceability and carrier schedules.
  • Best suited for panel builders, machine builders and process automation users who need relay-based timing control.

Contact UMA Industries for selection help, application matching and pan-India technical support.

UMA Industries manufactures and supplies the Digital Signal Operated Timer for industrial control panels that need a trigger-pulse start and a preset relay output. This Digital Signal Operated Timer is manufactured at UMA Industries’ unit in Village Sunped, Ballabgarh, Faridabad, Haryana, India, and supported across India for selection, integration and after-sales technical guidance. It is a practical choice for machine builders, panel builders and process plants that need repeatable timing after a start signal, rather than a continuously running timer.

Digital Signal Operated Timer for industrial trigger-pulse control

The Digital Signal Operated Timer is designed to begin timing when it receives a trigger pulse, then operate its relay when the preset time is reached. That makes it suitable where a machine cycle, process step or signal event must be converted into a controlled timed output. Because the timer uses a digital display and front-panel setting keys, it is easier to adjust than older mechanical timing devices when the application needs clear preset control. For many users, the main benefit is consistent signal-based timing with a straightforward operating sequence.

In day-to-day use, the Digital Signal Operated Timer is helpful when a short part-second input pulse must initiate a longer output duration. This is useful in automation panels, sequence control, machine logic and repeat-cycle tasks where the operator wants a visible preset value and a relay changeover at the end of the count. The product page and quotation discussion should always confirm the required timing unit, display setting and panel interface so the correct version is selected for the application.

Applications and typical use cases

The Digital Signal Operated Timer fits a wide range of industrial timing applications. It is commonly considered for control cabinets where a signal-triggered delay is required before a relay output changes state. Typical use cases include automation sequences, machine start-delay logic, count-and-hold timing, conveyor-related timing steps, and process equipment that must respond after a brief input pulse. It is also useful in retrofit work when an existing control panel needs a replacement timer with a clear display and simple key operation.

Because the unit operates from a trigger pulse, it is especially relevant where the timing event is not started manually every cycle. That makes the Digital Signal Operated Timer a logical choice for panel integrators who want the timer to follow the machine signal rather than a separate operator action. Buyers in Faridabad, Ballabgarh, and nearby manufacturing belts often use such timers in general automation, small machine controls and utility panels, while pan-India customers can specify the same device for similar process tasks.

When evaluating whether this product is appropriate, compare the signal type, preset range, required unit of seconds/minutes/hours, relay output expectation and panel space. If the cycle is simple, the Digital Signal Operated Timer can be a cost-effective solution; if the logic is more complex, it may be paired with counters, detectors or other control devices from the same family of industrial instruments.

Selection guidance and quotation-stage options

Selecting the right this product begins with the signal source and the intended timing sequence. Confirm whether the input is a short pulse, whether the time needs to be shown in seconds, minutes or hours, and whether the relay output should act as a direct machine command or as a pilot signal into another control stage. The current product copy states a range of 000 to 999 and a 3 digit LED display, while the actual setting method and final panel fit should be checked during quotation for the exact requirement.

Published prices on the website are company-confirmed. Product size, capacity, internal and external dimensions, power supply, optional controls/accessories, delivery schedule and mode of transport may be finalized or changed according to customer requirements in the quotation or proforma invoice. That flexibility is useful for panel builders because the this product may need to match the customer’s preferred enclosure layout, wiring practice or control philosophy.

If you are comparing this model with other timing or counting products, focus on the control job first: signal initiation, preset value, relay action and operator interface. For applications that need a different form of signal handling, buyers may also review Human Sensing Timer, Dosing Pump Timer, Counter with Timer and Digital Counter to match the logic more closely to the process.

Working principle, settings and operation

The this product works by receiving an input trigger pulse, then counting toward the preset value and energizing the relay when the selected time is achieved. The source copy describes a simple key sequence for set-up: press SET, use UP and DN to adjust the value, and press ENT to store it. It also mentions switching between seconds, minutes and hours, as well as selecting the decimal point when needed. These are practical features for operators who want a visible timing value and a direct user interface on the front panel.

For reliable use, the operating procedure should be built into the control-panel commissioning process. First, confirm the supply connection and signal input. Then set the required timing unit, enter the preset value, and verify that the relay changes state only after the trigger pulse has been received and the count is complete. When the this product is installed in a machine panel, the commissioning engineer should also confirm that the signal source is compatible with the intended input behaviour and that the relay contacts are used within their designed panel-control purpose.

Routine calibration, verification and panel checks

Although the product is straightforward to operate, routine verification is still important in industrial use. For the this product, check that the displayed preset matches the required process time, that the decimal point or time unit selection has not been altered, and that the relay operates at the expected point in the cycle. If the timer is used in a panel with vibration, heat, dust or frequent access, it is sensible to include it in the site’s routine electrical inspection schedule.

Verification should also include observation of the trigger-pulse input, the relay response and the stability of the preset value after repeated cycles. If a customer changes the machine logic later, the timer settings should be rechecked rather than assuming the original commissioning values are still correct. For a this product used in production equipment, small set-up errors can affect cycle timing, so the operator and maintenance staff should both understand the setting sequence.

Maintenance and safe installation practices

Maintenance for the this product is normally limited to keeping the panel clean, ensuring terminals are secure, and checking that the display remains readable under the installation lighting. Because the unit is used in industrial electrical panels, installation should be carried out by a qualified technician who understands supply isolation, wiring identification and relay interfacing. The body material is listed as ABS plastic, so the timer should be protected from unnecessary impact, excessive heat and incompatible cleaning practices.

Before putting the panel into service, verify terminal tightening, supply voltage, input signal routing and the correct relay load arrangement. In applications with frequent switching, the wiring and terminal condition should be included in periodic maintenance. If the this product is replaced during a shutdown, confirm the new unit’s set value, decimal setting and mode selection before restarting the machine. Good maintenance practice improves operating consistency and reduces unwanted downtime in the production line.

Faridabad manufacturing origin and pan-India support

Customers often want a supplier that can respond quickly to industrial queries, and that is why the manufacturing base matters. This this product is manufactured at UMA Industries’ unit in Village Sunped, Ballabgarh, Faridabad, Haryana, India. That Faridabad manufacturing origin is valuable for panel builders and machine users who need practical product guidance from a company that understands industrial control applications, not just catalog sales.

UMA Industries supplies and provides technical support to customers across India. For local buyers in Faridabad and the wider industrial belt, that means easier coordination during selection and commissioning. For outstation buyers, it means the same product knowledge can be used during quotation, dispatch planning and installation support. Ready-stock compact products, controllers, spares and accessories may be dispatched by air courier within 3 working days, subject to availability, payment confirmation, destination serviceability and carrier schedules. Delivery timelines for complete salt spray chambers and other large equipment are confirmed separately according to model, capacity, packing and freight mode.

For buyers comparing small control devices with related automation products, the same panel-building approach can be extended to items such as Digital Thickness Controller, Reject and Good Pcs detector and Tip and Bit Detector Controller, depending on the machine logic needed around the timer.

Digital Signal Operated Timer for panel builders

Panel builders usually look for a timer that is easy to wire, easy to explain to operators and easy to verify during installation. The this product suits that requirement because it combines digital preset entry with a relay output triggered by a signal event. When a panel designer needs a compact timing device for a machine sequence, the product can be matched to the required display format, timing unit and logic arrangement during quotation.

For integrators who routinely handle mixed control systems, the timer can also sit alongside sensing and monitoring products from the broader catalogue. Depending on the panel design, users may reference Humidity Sensor or tds meter modbus rtu rs485 when the job requires environmental or process measurement alongside timing control. The key point is to select each device for its own function instead of forcing one instrument to do every job.

Ordering, quotation and support

When you request a quotation for the this product, share the panel voltage, timing requirement, signal source and any preference for display or mounting style. Published prices on the website are company-confirmed, while the final installation details may be settled through quotation depending on the application. This helps keep the selected model aligned with the actual machine logic rather than a generic assumption.

If the timer is part of a larger machine project, UMA Industries can align the order with related panel items so that the electrical design remains consistent. The this product is often chosen for its simple set-up sequence and visible preset control, but the best result still comes from confirming the exact process requirement before purchase. For selection help, commercial discussion or technical guidance, contact UMA Industries by phone at 9310530941 or 8178668698.

Frequently asked questions

What does a Digital Signal Operated Timer do?

The this product receives a trigger pulse, counts to the preset time and then operates its relay. It is used when the timer must start from a signal rather than from a manual start every cycle.

How is the preset time set on this timer?

According to the supplied product copy, the this product is set by pressing SET, using UP and DN to adjust the value, and pressing ENT to save the preset. The timing unit can be selected between seconds, minutes and hours, and the decimal point can be adjusted if required.

Can this timer be used in industrial panels?

Yes. The this product is intended for industrial use in control panels, machine logic and automation sequences where relay-based timing after a trigger pulse is needed.

What display and supply details are mentioned for this model?

The source copy mentions a 3 digit LED display with 0.56 inch character height and a 220 Vac supply. These details should be reconfirmed for the exact order if the panel requirement is specific.

Is the timer suitable for replacement work?

Yes, the this product can be considered for replacement work when the existing circuit needs a trigger-operated digital timing device with similar supply and relay interface conditions.

How should the timer be maintained?

Keep the panel clean, check terminal tightness, verify the preset value periodically and make sure the relay output and trigger input still behave as intended. For the this product, maintenance is mainly about routine electrical inspection and correct commissioning.

Does UMA Industries support customers outside Faridabad?

Yes. UMA Industries supplies and provides technical support to customers across India, so the this product can be ordered for pan-India projects.

How do I request the correct version for my application?

Share the signal type, timing unit, preset requirement, supply conditions and panel layout. That helps ensure the this product is matched correctly during quotation rather than after installation.

For practical industrial timing control, the Digital Signal Operated Timer offers a simple trigger-based operating method, visible preset setting and support from UMA Industries’ Faridabad manufacturing base. If you need help matching the timer to your machine logic, contact UMA Industries for quotation and application guidance.


Need help choosing? Call/WhatsApp us for industrial pH/ORP solutions.


Weight500 g
Dimensions12 × 11 × 11 cm

Reviews

There are no reviews yet.

Be the first to review “Digital Signal Operated Timer Manufacturer in Faridabad”
🟢 WhatsApp Price 📞 Call Now
Scroll to Top