PH Sensor Lab Glass 1 Meter Cable
PH Sensor Lab Glass 1 Meter Cable is a laboratory-type glass pH electrode used with digital pH meters, table-top pH meters, online pH indicators and pH controllers for measuring acidity or alkalinity in water, chemical solutions, laboratory samples and process liquids. UMA Industries supplies pH sensors, pH electrodes, pH probes, pH meters, pH indicators and pH controllers for laboratories, RO plants, ETP/STP plants, chemical industries, water-treatment systems and industrial automation panels.
This lab glass pH sensor is suitable for sample testing and general pH measurement where a reliable glass electrode with 1 meter cable is required. It can be used in testing laboratories, educational institutes, water-quality labs, chemical labs, RO plant testing, process sampling and replacement applications for compatible pH instruments.
The PH Sensor Lab Glass 1 Meter Cable is commonly used when the existing pH electrode becomes slow, unstable, dry, damaged or inaccurate after regular use.

Technical Specifications of PH Sensor Lab Glass 1 Meter Cable
- Product Name: PH Sensor Lab Glass 1 Meter Cable
- Sensor Type: Laboratory glass pH electrode / pH sensor
- Measurement Parameter: pH
- Typical Range: 0.00 to 14.00 pH, depending on connected instrument
- Cable Length: 1 meter
- Body Type: Glass body
- Application: Laboratory pH meter, table-top pH meter, pH indicator and pH controller
- Connection: Suitable connector as per instrument model
- Use: Water, laboratory samples, process liquid, treated water, effluent and chemical solutions
- Compatible Instruments: Table-top pH meter, digital pH meter, online pH meter, pH indicator and pH controller
What is PH Sensor Lab Glass 1 Meter Cable?
PH Sensor Lab Glass 1 Meter Cable is a glass pH electrode used to sense hydrogen-ion activity in a liquid sample. The pH sensor sends a signal to the connected pH meter or pH controller, and the instrument displays the measured pH value digitally.
The pH sensor is the most important component in a pH measurement system. If the sensor is dirty, dry, cracked, aged or chemically damaged, the pH meter may show incorrect, unstable or slow readings. Proper cleaning, storage and calibration are necessary for reliable pH measurement.
Applications of PH Sensor Lab Glass 1 Meter Cable
Laboratory pH Testing
The sensor is suitable for laboratory sample testing, solution preparation, water-quality checking, chemical analysis and routine pH measurement.
Table-Top pH Meter
The lab glass pH sensor can be used with a compatible table-top pH meter for stable and convenient laboratory pH measurement.
Online pH Meter
The sensor can be connected with a compatible online pH meter for pH indication in sample lines, water-treatment panels and process monitoring systems.
pH Controller
pH controllers use the pH sensor signal to operate acid dosing, alkali dosing, alarm relay or process interlock according to the selected set point.
RO and DM Water Plants
RO and DM water systems use pH sensors for feed water, treated water, reject water, chemical dosing and final-water quality monitoring.
ETP and STP Plants
Effluent-treatment and sewage-treatment plants require pH sensors for neutralisation, treated-water checking and discharge monitoring.
Chemical Laboratories
Chemical laboratories use glass pH electrodes for testing acidic and alkaline solutions, process samples, dilution water and prepared chemical solutions.
Food and Beverage Testing
Food and beverage laboratories use pH sensors for treated water, process water, cleaning-water systems and sample-quality checking.
Pharmaceutical and Research Labs
Pharmaceutical utilities, research laboratories and quality-control departments use pH sensors for purified-water testing, sample preparation and documentation.
Educational Institutes
Schools, colleges, universities and technical institutes use lab glass pH sensors for chemistry labs, water-quality experiments and training applications.
Why Choose PH Sensor Lab Glass 1 Meter Cable?
- Suitable for laboratory pH meter and table-top pH meter applications
- Glass electrode for reliable pH sensing
- 1 meter cable for convenient connection
- Useful replacement sensor for old or damaged pH electrodes
- Suitable for RO, ETP, STP and laboratory testing
- Can be used in industrial and educational applications
- Easy calibration using standard pH buffer solutions
- Compatible with pH measurement and pH control systems
When Should You Replace a pH Sensor?
- Reading is slow even after cleaning and calibration
- Reading is unstable or continuously drifting
- Calibration cannot be completed correctly
- Glass bulb is cracked or physically damaged
- Sensor was kept dry for a long time
- Electrode cable or connector is damaged
- Reading does not match standard buffer solution
- pH meter display changes randomly without sample change
Compatible pH Instruments
- Table-Top Laboratory pH Meter – Suitable for laboratory sample testing.
- Digital pH Meter Online – Panel-mounted pH meter for continuous pH indication.
- pH Meter with 4-20 mA Output – Suitable for PLC, recorder and SCADA applications.
- pH Meter with 0-10 VDC Output – Suitable for analog monitoring systems.
- RS485 Modbus RTU pH Controller – Suitable for PLC, HMI and SCADA integration.
- pH Controller with One Relay – Suitable for dosing and alarm applications.
- pH Controller with Two Relay Outputs – Suitable for acid and alkali dosing control.
View more products in our pH Meter product category and pH Controller category.
Calibration Procedure for PH Sensor Lab Glass 1 Meter Cable
Prepare the Sensor
- Connect the pH sensor to the compatible pH meter or pH controller.
- Switch ON the instrument and allow it to stabilise.
- Remove the sensor from storage solution.
- Rinse the glass bulb gently with clean or distilled water.
- Do not touch or rub the glass bulb.
Calibrate at 7.00 pH
- Dip the sensor into fresh 7.00 pH buffer solution.
- Wait until the reading becomes stable.
- Adjust the 7 pH calibration setting on the instrument.
- Set the display to exactly 7.00 pH.
Calibrate at 4.00 pH
- Remove the sensor from 7.00 pH buffer and rinse it with clean water.
- Dip the sensor into fresh 4.00 pH buffer solution.
- Wait until the reading becomes stable.
- Adjust the 4 pH or slope calibration setting.
- Set the display to exactly 4.00 pH.
Final Verification
- Rinse the sensor after calibration.
- Recheck the reading in 7.00 pH buffer solution.
- Repeat calibration if the reading is not correct.
- Start sample testing after successful calibration.
Installation and Use Instructions
- Use the pH sensor with a compatible pH meter or pH controller.
- Keep the glass bulb wet before measurement.
- Dip the bulb properly into the sample during testing.
- Avoid air bubbles around the sensing bulb.
- Do not allow the sensor cable to pull or twist during use.
- Keep the sensor cable away from motor, VFD and power wiring in industrial panels.
- Use a suitable holder, stand, sample cup, flow cell or chamber as per application.
- Provide easy access for sensor cleaning, storage and calibration.
Storage Instructions for PH Sensor Lab Glass 1 Meter Cable
- Store the pH sensor in proper electrode-storage solution.
- Do not keep the glass bulb dry.
- Do not store the pH sensor in distilled water or DM water for a long time.
- Keep the protective cap fitted when the sensor is not in use.
- Store the sensor in a clean and safe place to avoid glass damage.
Work Instructions and Precautions
- Do not touch the glass bulb with fingers.
- Do not rub the glass bulb with cloth or hard material.
- Use fresh pH buffer solution for calibration.
- Do not return used buffer solution to the original bottle.
- Clean the sensor according to sample contamination.
- Avoid sudden mechanical shock to the glass body.
- Do not pull the sensor by cable.
- Check cable and connector condition before use.
- Replace the sensor if calibration is not possible after cleaning.
Cleaning of PH Sensor Lab Glass 1 Meter Cable
The cleaning method depends on the type of contamination on the pH sensor. General deposits can be removed by gentle rinsing with clean water. Oily deposits, chemical coating, scale or biological fouling may require proper cleaning solution according to the application.
After cleaning, rinse the sensor with clean water, keep it in storage solution for some time and then perform calibration with fresh 7.00 pH and 4.00 pH buffer solutions.
Difference Between Lab pH Sensor and Industrial pH Sensor
A lab pH sensor is generally used for sample testing, laboratory work and controlled measurement conditions. An industrial pH sensor may have stronger body construction, longer cable, process connection, high-temperature suitability or special chemical resistance depending on the application. Correct sensor selection depends on liquid type, temperature, pressure, contamination and installation method.
Difference Between pH Sensor, pH Electrode and pH Probe
In practical use, the terms pH sensor, pH electrode and pH probe are commonly used for the sensing part that measures pH. The sensor generates the signal, while the pH meter or pH controller displays and processes the measured pH value.
Related Water Quality Instruments
- Digital pH Meter Online – For continuous pH measurement in water and process liquids.
- pH Meter with 4-20 mA Output – For PLC, recorder and SCADA systems.
- RS485 Modbus RTU pH Controller – For PLC, HMI and SCADA integration.
- pH Controller with One Relay – For chemical dosing and alarm applications.
- pH Controller with Two Relay Outputs – For acid and alkali dosing control.
- Table-Top Laboratory pH Meter – For laboratory sample testing.
- pH Sensor and Electrode – Replacement electrode for pH meters and controllers.
Industries Using PH Sensor Lab Glass 1 Meter Cable
- Testing laboratories
- Educational institutes
- RO plant manufacturers
- ETP and STP contractors
- Water-treatment companies
- Pharmaceutical industries
- Food and beverage industries
- Chemical industries
- Electroplating industries
- Textile and dyeing industries
- Cooling-tower water-treatment companies
- Control-panel manufacturers
7 Powerful Benefits of PH Sensor Lab Glass 1 Meter Cable
- Reliable replacement sensor for pH measurement
- Suitable for laboratory and table-top pH meters
- Useful for RO, ETP, STP and sample-testing applications
- Glass sensing bulb for pH detection
- 1 meter cable for convenient connection
- Simple calibration using standard buffer solutions
- Suitable for water-quality and chemical-sample monitoring
FAQs About PH Sensor Lab Glass 1 Meter Cable
What is PH Sensor Lab Glass 1 Meter Cable?
It is a laboratory glass pH electrode with 1 meter cable used to measure pH when connected with a compatible pH meter, pH indicator or pH controller.
Where is this pH sensor used?
It is used in laboratories, RO plants, ETP plants, STP plants, water-treatment systems, chemical testing, educational institutes and industrial pH measurement applications.
Can this sensor be used with a table-top pH meter?
Yes, it can be used with a compatible table-top pH meter after confirming connector type and sensor compatibility.
Can this sensor be used with an online pH meter?
Yes, it can be used with a compatible online pH meter after checking sensor and connector compatibility.
Can this sensor be used with a pH controller?
Yes, it can be used with a compatible pH controller for dosing, alarm or pH control applications.
What is the cable length?
The cable length is 1 meter.
Is it a glass pH electrode?
Yes, this product is a laboratory glass pH sensor / glass pH electrode.
How should the pH sensor be stored?
The pH sensor should be stored in proper electrode-storage solution. It should not be kept dry for long periods.
Can the pH sensor be stored in distilled water?
No, long-term storage in distilled water or DM water is not recommended for standard glass pH electrodes.
How is the pH sensor calibrated?
The sensor is calibrated with the connected instrument using fresh 7.00 pH and 4.00 pH buffer solutions.
When should the pH sensor be replaced?
Replace the sensor if readings are slow, unstable, incorrect, if calibration fails, or if the glass bulb or cable is damaged.
Do you supply pH meters and pH controllers also?
Yes, UMA Industries supplies pH sensors, online pH meters, digital pH indicators, table-top pH meters, pH controllers and industrial water-quality instruments.
Do you supply throughout India?
Yes, we supply pH sensors, pH electrodes, pH meters and pH controllers throughout India.
External Technical References
Business Partner and Dealer Opportunity
Dealers, distributors, RO plant manufacturers, ETP/STP contractors, laboratory-equipment suppliers, educational-instrument suppliers, control-panel manufacturers and industrial-instrument dealers may contact UMA Industries for business cooperation involving pH sensors, pH electrodes, pH meters, pH controllers and industrial water-quality instruments.
Our Other Websites
- phmeters.in – pH meters, pH controllers, electrodes and industrial instruments.
- salt-spray-chamber.in – Salt spray chambers and corrosion-test equipment.
- water-tank.in – Water-storage and chemical-storage tanks.
- YouTube Channel – Product demonstrations and updates.
- MCS Facebook Page – Product news and updates.
- Robotech Learning Channel – Technical tutorials and product videos.
Buy PH Sensor Lab Glass 1 Meter Cable
Contact UMA Industries for pricing, compatibility confirmation, connector details, electrode selection and correct model recommendations. We supply PH Sensor Lab Glass 1 Meter Cable, pH electrodes, table-top pH meters, online pH meters, pH controllers and industrial water-quality instruments throughout India.
Need help choosing? Call/WhatsApp us for industrial pH/ORP solutions.



Reviews
There are no reviews yet.