Safety Light Curtain MCS-4016-NJ
Hence The Diamentions of Safety Light Curtain, Safety Light Curtain MCS-4016-NJ
OVERALL HEIGHT(MM) : 700 MM
PROTECTED HEIGHT(MM) : 640 MM
NO OF BEAM: 16 BEAM
PITCH: 40 MM
output PNP or NPN/ NC
Output indications Through corresponding LEDs
Sensor Power Supply 12-24 volts DC
Response time On to off:10-15 msec.
Operating Temperature Up to 55 Degrees centigrade
Protections Output short circuit protected
Aluminium Cross Section 50X36 mm
Accessories Required Specifications:
To operate / working of Safety Light Curtain few more additional product may required for installation;Â we given a brief with product catalog link here
Controller for safety Light Curtain :
Power Supply Controller 220 VAC;
Relay Output ; 1 or 2 relay
Cable Set For Safety Light Curtain
Two Cables are Required for Installation
- Emitter cable length 5 Meter
- Â Reciever Cable Length 3 Meter
- with suitable Connectors at one End
Other Models in This Category:
- Safety Light Curtain SLC-0630
- Safety Light Curtain SLC-1030
- Safety Light Curtain SLC-1230
- Safety Light Curtain SLC-1630
- Safety Light Curtain SLC-1830
- Safety Light Curtain SLC-2430
- Safety Light Curtain SLC-3030
- As per Demand special orders
Others Technical Specifications: Safety Light Curtain MCS-4016-NJ
Hence Sensor Power Supply : 12-24 volts DC
While output ; PNP or NPN/ NC
But Output indications ; Through corresponding LEDs
Hence Response time On to off : 10-15 msec.
While No of beams : 8,10,12,16, 18, 24, 30, or as required
But Beam bypass Provided in Controller
Also Adjustable Range Up to 3 meters
Hence Higher Sensing range up to 5,10,15 meter. available on demand
While Standard Cable length 5 meters for the emitter, 3 meters for the receiver
But Operating Temperature Up to 55 Degrees centigrade
Protections Output short circuit protected
Suitable for Machines with quick emergency stop
FEATURES:-
Hence An ISO 9001:2015 Certified Company, 2 Outputs model also available,
Hence Safety Light curtains must comply with IEC-61496 parts 1 & 2. While as ANSI/UL 61496 parts 1 & 2. Light curtains’ “TYPE” their Safety Performance Level. Hence it must be appropriately selected. Light curtains’ optional functions. Because as listed in Annex “A” of IEC-61496 part 1, must comply with Annex “A” requirements.
working Principle:
Hence A safety light curtain consists of two parts: Transmitter + Receiver. While The transmitter contains multiple Infrared LEDs that send pulses of infrared light to the receiver. When an interrupt occurred between the transmitter and receiver then we receive an output that used to stop working or raise alarm.
pH Meter
Like MCS Facebook Page for recent offers & Updates!
Reviews
There are no reviews yet.