Sale!

Original price was: ₹5,000.00.Current price is: ₹3,700.00.

- +
Guaranteed Safe Checkout

Online PH Meter Mumbai

10 Days Returnable;
Heavy Duty Industrial Use
1 Year Warranty and nominal Life 6-7 years in a Normal Atmosphere.
Sensors No Warranty.”

Contact Us:- 8178668698; 9310530941; An ISO 9001-2015 Certified Company.

 

Online PH Meter Mumbai – Digital pH Meter for Industrial Water Monitoring

UMA Industries supplies reliable Online PH Meter Mumbai
solutions for continuous measurement of water, wastewater, chemical solutions
and industrial process liquids. Our panel-mounted instruments are suitable for
ETP plants, STP plants, RO plants, DM plants, electroplating units, chemical
industries, textile processing, pharmaceutical utilities, food-processing
plants, cooling towers and boiler-water treatment systems.

Online PH Meter Mumbai
Digital online pH meter for continuous industrial water, wastewater and
process-liquid monitoring.

Industrial Online PH Meter Mumbai

An Online PH Meter Mumbai continuously receives the electrical
signal generated by a compatible pH electrode and converts it into a readable
digital pH value. The instrument enables operators to observe the process
continuously instead of collecting samples and testing them manually at long
intervals.

The pH scale normally extends from 0 to 14. A value below 7 indicates an acidic
condition, a value of 7 is neutral and a value above 7 indicates an alkaline
condition. Maintaining the required pH is important for chemical dosing,
wastewater neutralisation, product quality, corrosion control, treatment
efficiency and process consistency.

Depending on the selected model, the meter can provide relay outputs, high and
low pH alarms, acid or alkali dosing control, 4–20 mA output, 0–10 VDC output
or RS485 Modbus RTU communication. This allows integration with dosing pumps,
control panels, PLCs, HMIs, SCADA systems, recorders and data loggers.

Main Features of Online PH Meter Mumbai

  • Continuous online measurement of water and process-liquid pH
  • Common measuring range from 0.00 to 14.00 pH
  • Bright digital LED display for clear process indication
  • Panel-mounted design for industrial control panels
  • Standard input for a compatible pH electrode with BNC connector
  • Two-point calibration using standard buffer solutions
  • High and low pH set-point options, depending on model
  • Relay output for alarm, dosing pump, valve or interlocking
  • Optional 4–20 mA analogue retransmission output
  • Optional 0–10 VDC output for compatible automation systems
  • Optional RS485 Modbus RTU communication
  • Suitable for tank, pipeline, flow-cell and sampling-pot installation
  • Compatible with PLC, SCADA, HMI and data-logging systems
  • Suitable for continuous industrial water-quality monitoring

Technical Specifications of Online PH Meter Mumbai

The following are typical specifications for an
Online PH Meter Mumbai. Final specifications depend on the
selected model, sensor, control outputs, communication requirement and
installation conditions.

Technical ParameterTypical Specification
Measured parameterpH
Measurement range0.00 to 14.00 pH
DisplayBright digital LED display
Measurement methodContinuous online measurement using a combination pH electrode
Sensor connectionBNC connector for a compatible pH probe
CalibrationTwo-point calibration using pH 4.00 and pH 7.00 buffers
Additional calibration bufferpH 9.18 or pH 10.00 for suitable alkaline-range applications
Set pointsHigh and low pH set-point options, depending on model
Relay outputAvailable for alarm, dosing pump, valve or interlocking
Analogue output4–20 mA or 0–10 VDC through selected models
Digital communicationRS485 Modbus RTU through the Modbus model
Temperature compensationManual or automatic, depending on model and sensor
MountingPanel-mounted industrial design
Electrode installationTank, pipeline, flow cell, sampling chamber or immersion assembly
Power supplyModel-dependent industrial AC or DC supply
ApplicationsETP, STP, RO, DM, chemical, plating, textile and utility systems

Working Principle of an Online pH Meter

The pH electrode contains a sensitive glass membrane and a reference system.
When the electrode is immersed in the process liquid, it develops a small
electrical potential related to hydrogen-ion activity. The online meter
receives this signal, applies the calibration values and displays the
corresponding pH reading.

In a typical installation, the electrode is mounted in a process tank,
neutralisation chamber, pipeline, flow cell or sampling pot. The panel meter
displays the live pH value so that the operator can identify changes in process
conditions immediately.

Models with relay outputs can activate an alarm or dosing arrangement when the
pH crosses a programmed set point. Models with analogue or digital communication
can transmit the measured value to a PLC, SCADA system, recorder or central
monitoring dashboard.

Online pH Meter and pH Controller Difference

An online pH meter primarily measures and displays the current pH value. A
pH controller provides additional control functions, such as relay outputs
for operating acid pumps, alkali pumps, solenoid valves, alarms or process
interlocks.

Users who only require continuous indication can select a standard digital
pH meter. Users who need automatic chemical correction should select a pH
controller with the appropriate number of set points and relay outputs.

Calibration of Online PH Meter Mumbai

Correct calibration is essential for dependable operation of an
Online PH Meter Mumbai. A pH electrode changes gradually due
to ageing, coating, contamination, chemical exposure and temperature. Regular
cleaning and calibration compensate for these changes.

Items Required for Calibration

  • Fresh pH 7.00 buffer solution
  • Fresh pH 4.00 buffer solution
  • pH 9.18 or pH 10.00 buffer for suitable alkaline applications
  • Clean distilled or demineralised water
  • Separate clean beakers for each buffer
  • Soft tissue for gently removing excess water
  • Calibration and maintenance record sheet

Step-by-Step Calibration Procedure

  1. Switch on the online pH meter and allow the instrument to stabilise.
  2. Remove the electrode carefully from the tank, flow cell or sampling chamber.
  3. Inspect the glass bulb, cable and BNC connector for deposits, moisture or
    physical damage.
  4. Rinse the electrode with distilled or demineralised water.
  5. Gently shake off excess water. Do not rub or scratch the sensitive glass bulb.
  6. Immerse the electrode in fresh pH 7.00 buffer solution.
  7. Wait until the displayed value becomes stable.
  8. Perform the neutral or pH 7 calibration according to the instrument controls.
  9. Remove the electrode and rinse it again with clean water.
  10. Immerse the electrode in pH 4.00 buffer for acidic-range applications.
  11. For alkaline-range measurement, use a suitable pH 9.18 or pH 10.00 buffer.
  12. Wait for reading stability and perform the second calibration point.
  13. Rinse the electrode and verify the reading again in pH 7.00 buffer.
  14. Reinstall the electrode and confirm that the live process reading is stable.
  15. Record the calibration date, buffer values and final readings.

Recommended Calibration Frequency

Calibration frequency depends on the liquid, operating temperature,
contamination and accuracy requirement. Instruments used with relatively clean
water may be calibrated weekly, fortnightly or monthly. Applications involving
wastewater, sludge, plating chemicals, oil, suspended solids or aggressive
solutions may require more frequent cleaning and calibration.

Replace the pH electrode when it responds very slowly, fluctuates continuously
or cannot be calibrated correctly even after cleaning.

Applications of Online PH Meter Mumbai

The Online PH Meter Mumbai is suitable for industrial
applications where continuous liquid monitoring is required for treatment,
quality control, dosing or process stability.

  • Effluent Treatment Plants:
    Monitoring wastewater during collection, treatment, neutralisation and final
    discharge.
  • Sewage Treatment Plants:
    Monitoring inlet water, biological-treatment stages and final treated water.
  • RO and DM Plants:
    Measuring feed water, treated water, reject water and chemical-dosing stages.
  • Electroplating Industries:
    Monitoring pretreatment baths, rinse tanks, plating solutions and effluent.
  • Chemical Industries:
    Measuring reaction liquids, mixing tanks, dosing systems and neutralisation
    vessels.
  • Textile and Dyeing Units:
    Monitoring bleaching, dyeing, washing, finishing and wastewater processes.
  • Pharmaceutical Utilities:
    Monitoring process water, cleaning solutions and utility-treatment systems.
  • Food and Beverage Plants:
    Monitoring process liquids, utility water, cleaning systems and wastewater.
  • Boiler-Water Treatment:
    Supporting chemical treatment, corrosion control and water-quality monitoring.
  • Cooling Towers:
    Monitoring circulating water and chemical-treatment systems.
  • Paper and Pulp Industries:
    Monitoring process water, pulp treatment and industrial effluent.
  • Aquaculture:
    Continuous monitoring of water in fish tanks, ponds and recirculation systems.

Benefits of Continuous Online pH Monitoring

  • Real-time display of process pH
  • Reduced requirement for repeated manual sampling
  • Faster detection of abnormal acidic or alkaline conditions
  • Improved wastewater-treatment consistency
  • Better chemical-dosing control
  • Reduced risk of excessive acid or alkali dosing
  • Improved product and process repeatability
  • High and low pH alarm options
  • Optional automatic dosing-pump control
  • Optional PLC, SCADA and data-logging integration
  • Improved maintenance and process records

Selection of a Suitable pH Electrode

The electrode is the sensing component of the measurement system. Selecting
the correct probe is essential because one type of electrode may not be
suitable for every chemical, temperature or installation.

  • General-purpose glass electrode for relatively clean water
  • Industrial immersion electrode for tanks, sumps and ETP systems
  • Flow-through electrode for pipelines and sampling chambers
  • Double-junction electrode for contaminated process liquids
  • Flat-surface electrode for viscous or semi-solid samples
  • High-temperature electrode for heated process liquids
  • Long-cable electrode for deep tanks and remote installation
  • Chemical-resistant electrode for aggressive industrial solutions

Installation Guidelines

  1. Install the meter inside a clean and dry control panel.
  2. Protect the instrument from direct water spray, chemical fumes and excessive
    temperature.
  3. Install the electrode where the liquid is representative and properly mixed.
  4. Avoid installing the sensor directly beside an acid or alkali injection point.
  5. Keep the glass sensing bulb continuously immersed during measurement.
  6. Avoid locations where air bubbles collect around the electrode bulb.
  7. Keep the pH electrode cable separate from motor, VFD and high-voltage cables.
  8. Provide correct electrical earthing to reduce unstable readings.
  9. Use a suitable flow cell where direct tank installation is not practical.
  10. Provide enough space to remove the electrode for cleaning and calibration.

Maintenance and Safety Precautions

  • Never allow the glass sensing bulb to remain dry.
  • Store the electrode in the recommended electrode-storage solution.
  • Do not permanently store the electrode in distilled or DM water.
  • Do not clean the glass bulb with abrasive material or hard tools.
  • Use fresh and uncontaminated buffer solutions.
  • Never return used calibration buffer to its original container.
  • Clean oil, scale, sludge and chemical deposits regularly.
  • Check the sensor cable and BNC connector for moisture or damage.
  • Keep water and chemical leakage away from the instrument panel.
  • Use suitable PPE while handling acids, alkalis and process chemicals.

Online PH Meter Mumbai Supply Areas

UMA Industries supplies Online PH Meter Mumbai products to
water-treatment companies, panel builders, ETP contractors, automation
companies, laboratories and industrial users throughout Mumbai, Navi Mumbai,
Thane and the surrounding Maharashtra industrial belt.

Mumbai Industrial Areas

  • Andheri East
  • Marol Industrial Estate
  • Saki Naka Industrial Area
  • Chandivali
  • Powai
  • Goregaon Industrial Area
  • Malad Industrial Area
  • Kandivali Industrial Estate
  • Kurla Industrial Area
  • Chembur and Trombay industrial belt

Nearby Industrial Areas and Cities

  • Thane:
    Wagle Industrial Estate, chemical plants, engineering units and
    water-treatment companies.
  • Navi Mumbai:
    Rabale, Mahape, Turbhe, Pawane, Kopar Khairane and TTC Industrial Area.
  • Taloja:
    Chemical, pharmaceutical, food-processing and effluent-treatment plants.
  • Panvel:
    Engineering, logistics, chemical and water-treatment applications.
  • Dombivli:
    Chemical, textile, engineering and manufacturing industries.
  • Kalyan:
    Process plants, fabrication units and industrial utility systems.
  • Bhiwandi:
    Textile, warehousing, food-processing and manufacturing units.
  • Ambernath and Badlapur:
    Chemical, pharmaceutical, engineering and process industries.
  • Vasai and Virar:
    Plastic, fabrication, electrical and general manufacturing units.
  • Boisar and Tarapur:
    Chemical, textile, pharmaceutical and large process industries.
  • Patalganga and Rasayani:
    Petrochemical, chemical and industrial water-treatment plants.
  • Pune and Chakan:
    Automotive, engineering, pharmaceutical and industrial process plants.
  • Nashik:
    Food, pharmaceutical, electrical and engineering industries.

Other Products in the pH Meter Category

Buyers selecting an Online PH Meter Mumbai can compare the
following related UMA Industries products for standard monitoring, automatic
control, analogue transmission, Modbus communication and laboratory testing.

External Technical Reference

For additional scientific information about pH, hydrogen-ion activity and its
effect on water chemistry, visit the

United States Environmental Protection Agency technical reference on pH
.

Frequently Asked Questions

What is an online pH meter?

An online pH meter is an industrial instrument that continuously measures
the pH of water, wastewater, chemicals or process liquids through a connected
pH electrode.

Where is an online pH meter installed?

The electrode can be installed in a tank, pipeline, flow cell, sampling pot,
neutralisation chamber, effluent channel or treatment system. The display
unit is normally installed in a control panel.

What is the normal pH measurement range?

The commonly available measurement range is 0.00 to 14.00 pH. The final
specification should be confirmed for the selected model.

Which buffers are used for calibration?

pH 7.00 and pH 4.00 buffers are commonly used for two-point calibration.
A pH 9.18 or pH 10.00 buffer may be selected for an alkaline-range application.

How often should an online pH meter be calibrated?

Calibration may be required weekly, fortnightly or monthly depending on the
application. Wastewater, chemical and contaminated processes may require
more frequent calibration.

Can an online pH meter control a dosing pump?

Models with relay or controller outputs can operate acid or alkali dosing
systems. Larger pumps should be connected through correctly rated contactors
or interposing relays.

Is 4–20 mA output available?

Yes. A selected model is available with 4–20 mA output for PLC, SCADA,
recorder and remote-display applications.

Is RS485 Modbus communication available?

Yes. A Modbus 485 pH meter is available for integration with compatible PLC,
HMI, SCADA and industrial data systems.

Why does the pH reading fluctuate?

Common causes include a dirty or dry electrode, damaged sensor cable, air
bubbles, electrical noise, poor earthing, old buffer solution, inadequate
mixing or an ageing electrode.

Can one pH electrode measure every chemical?

No. Electrode selection depends on chemical compatibility, temperature,
pressure, suspended solids, contamination and installation method.

Can the electrode be stored dry?

A standard glass pH electrode should not be stored dry. Use the recommended
electrode-storage solution when it is removed from service.

Where can I buy Online PH Meter Mumbai?

UMA Industries supplies Online PH Meter Mumbai products to
Mumbai, Thane, Navi Mumbai, Taloja, Rabale, Mahape, Turbhe, Dombivli,
Bhiwandi, Vasai, Boisar, Tarapur and other Maharashtra industrial locations.

What details are required for selecting the meter?

Provide the process-liquid name, expected pH range, temperature, pressure,
tank or pipeline arrangement, required cable length, relay requirement,
analogue output, communication requirement and installation location.

Order Online PH Meter Mumbai

For selecting the correct Online PH Meter Mumbai, share your
application details, process-liquid condition, measurement range, temperature,
electrode mounting method and required outputs. UMA Industries can recommend
a suitable digital meter, industrial electrode, relay-output model or
communication-enabled instrument for your application.


Contact UMA Industries for online pH meters, digital pH controllers,
industrial pH electrodes, 4–20 mA meters and RS485 Modbus instruments.


Need help choosing? Call/WhatsApp us for industrial pH/ORP solutions.


Weight500 g